Documentation · BR2006

BR2006 documentation for CemPU

Consolidated documentation pack for authority approval under the Building Regulation for Greenland: fire class A2-s1,d0 under EN 13501-1, U-value 0.079 W/m²K, structural calculations for arctic snow and wind loads, moisture engineering and acoustics. Structured for architects, consulting engineers, contractors and developers in Greenland.

Fire compliance

A2-s1,d0 opens the doors to more than single-family houses

The fire classification is the single point that most often determines which building types a facade element can be used for in Greenland. This is where CemPU's decisive difference from competing steel panels lies.

A2-s1,d0 — what does the classification mean? A2 = limited contribution to fire (class A1 is fully non-combustible; A2 is virtually non-combustible). s1 = very limited smoke development. d0 = no flaming droplets. Classified under EN 13501-1 — the European harmonised fire standard recognised by BR2006.
Why it matters in Greenland BR2006 imposes stricter requirements on load-bearing and separating constructions in multi-storey housing, day-care institutions, care homes, schools, commercial and industrial halls. Combustible facade materials (B/C/D class) are typically refused or require compensating measures that make the project uneconomical. A2 removes that barrier.
Competing systems typically classify lower Steel panels with PIR core classify as B-s2,d0. Steel panels with PUR foam typically C-s3,d0. Mineral wool panels can reach A2, but at the expense of U-value and weight. Many Greenlandic developers only encounter this difference when the authority refuses the project.
The consequence for project economics With an A2-approved building envelope, the same prefab product can be used from single-family houses to 4-storey housing and institutions. That means a single supplier, known details, one consolidated documentation pack and predictable authority handling — instead of switching building system per building category.

CemPU vs. PIR/PUR panels

PropertyCemPUPIR/PUR steel
Fire class (EN 13501-1)A2-s1,d0B-s2,d0 to C-s3,d0
U-value (300 mm)0.079 W/m²K0.11–0.15 W/m²K
Lambda0.023 W/mK0.022–0.025 W/mK
Multi-storey housing BR2006SuitableTypically refused
Institutions BR2006SuitableTypically refused
Industrial halls BR2006SuitableLimited — sprinkler typically required
Single-family housesSuitableSuitable
Load-bearing constructionSandwich, both skinsSteel facing, not load-bearing
Diffusion-tight coreYes (closed-cell PU)Yes (PIR/PUR)

Competitor data are typical ranges for steel sandwich panels in the Nordic market. Exact values depend on manufacturer — verification per project recommended.

Read the in-depth comparison
Five areas

Documentation areas under BR2006

The same documentation structure required by the authority application. Each area can be extracted and used directly in the project material.

Documentation pack

Documentation for BR2006 application

The consolidated pack typically requested by Greenlandic authorities, municipalities and developers. Adapted per project — building category, load zone and element build-up determine which parts are relevant.

Data sheets — direct download

Sales material with technical core data, comparisons and BR2006 perspectives. No login required.

Actual reports — on request

Original test and certification reports issued by accredited laboratories and notified bodies. Sent on request to specific projects.

Note: Actual reports are tailored to the specific Greenlandic project — load zone, building category under BR2006, element build-up and installation window are all part of the project-specific pack. Send drawings and project description, and we will compose the relevant documentation. Delivery time typically 1–5 working days depending on scope.

FAQ

Frequently asked questions about BR2006 documentation

The questions we are asked most frequently by architects, consultants and developers designing under the Building Regulation for Greenland.

What does fire class A2-s1,d0 mean?

The classification is defined in EN 13501-1. A2 means limited contribution to fire — the second-highest class for construction products (only A1 is higher and covers fully non-combustible materials). s1 means very limited smoke development. d0 means no flaming droplets. Together this is the classification that qualifies CemPU for building categories where combustible materials are refused.

Can CemPU be used for multi-storey housing and institutions in Greenland?

Yes. A2-s1,d0 under EN 13501-1 makes CemPU suitable for multi-storey housing, day-care institutions, care homes, schools, commercial buildings and industrial halls under BR2006. Competing steel panels with PIR/PUR foam (typically B-s2,d0 or C-s3,d0) are often refused for these categories or require compensating measures that make the project uneconomical.

What snow loads is CemPU dimensioned for?

Dimensioning is per project under EN 1991-1-3 and BR2006 zone-specific characteristic snow loads. Typical Greenlandic requirements range 2.5–4.0 kN/m² on the ground, but in highland areas and certain coastal towns values of 5.0+ kN/m² may occur. Stamped structural documentation is delivered per project.

What wind loads does CemPU handle?

Wind load under EN 1991-1-4 with Greenlandic basic wind speeds. Certain zones — particularly coastal towns in South Greenland and mountain areas — have dimensioning wind speeds up to 55+ m/s with gusts above. The sandwich construction distributes wind load across both cement skins and provides high stiffness per wall unit.

How is freeze-thaw resistance documented?

The cement skins are tested under CEN/TS 12390-9 (freeze-thaw resistance for concrete). The inorganic cement matrix has no capillary suction of free water and is non-hygroscopic, eliminating the volume expansion in freeze cycles that destroys porous facade materials. The PU core is closed-cell and diffusion-tight — no water uptake and therefore no frost damage in the core.

What U-value is achieved — and does it hold in practice?

U-value 0.079 W/m²K with a 300 mm PU core (lambda 0.023 W/mK). The continuous insulation without mechanical breaks means the documented laboratory value actually holds in the finished construction. This is critical in arctic climate where even small thermal bridges cause moisture problems at large temperature gradients between indoor and outdoor.

What acoustic properties are documented?

R'w 42–48 dB depending on build-up and joints. For residential separations and institutional applications we deliver recommended build-ups that meet BR2006's acoustic requirements. Double-wall constructions and floor solutions are documented per project.

Is CemPU CE marked and recognised under BR2006?

Yes. CemPU is documented under EN 14509 (self-supporting sandwich panels with insulation core) and is supplied with a Declaration of Performance (DoP) and ETA basis. CE marking is recognised under BR2006 in Greenland as documentation of essential properties such as fire, mechanical resistance and energy.

How quickly can you deliver the documentation pack?

General documentation (fire, U-value, materials, CE) is typically delivered within 1–2 working days. Project-specific structural documentation takes 3–5 working days depending on complexity and load zone. Send drawings and building category, and we will assess the scope.

Need BR2006 documentation for your Greenland project?

Send project description, building category and drawings. We compose the documentation pack that matches your specific project — from fire and U-value to project-specific structural calculations for snow and wind load.