In a nutshell
- BR2006 fire: Institutions require A2-s1,d0 fire class on load-bearing structure — CemPU is approved directly
- R'w 50 dB: Residential separating walls and classrooms require at least 50 dB sound reduction — CemPU reaches 42–48 dB, possibly with additional measures
- U-value tightening: Institutions in cold areas require U <0.15 W/m²K — CemPU 336 mm = 0.079 delivers significant over-dimensioning
- Accessibility: BR2006 §6 requires wheelchair access and wide doors — CemPU's dry assembly delivers precise openings
- Settlement adaptation: Tekment delivers project-specific panels to settlement schools typically 200–500 m²
What requirements does BR2006 set for institutional construction?
BR2006 sets stricter requirements for institutional construction (schools, daycare, health centres) in five areas:
1. Fire: Load-bearing constructions must be A1 or A2-s1,d0 per EN 13501-1. REI 60 for school buildings over 1 storey. Fire compartmentation every 600 m².
2. Acoustics: R'w >50 dB between classrooms, R'w >55 dB between classroom and corridor.
3. Energy: U-value <0.15 W/m²K on external wall, <0.10 W/m²K on roof — stricter than residential.
4. Accessibility: Wheelchair access, wide doors (min. 90 cm), accessible toilets, level access.
5. Indoor climate: Ventilation min. 8 l/s per person, CO₂ level below 1,000 ppm in classrooms.
Why is the A2 fire class decisive for settlement institutions?
In settlements, distances to emergency services are large — typically the nearest fire service in the municipal centre is 50–200 km away. This makes the fire safety of the building itself extra critical. BR2006 reflects this: institutions in settlements may only be built with A1- or A2-classified materials on the load-bearing structure. Traditional PIR/PUR panels (B-s2,d0 to C-s3,d0) are not approved as a starting point. CemPU's A2-s1,d0 is "limited contribution to fire" — inorganic cement surfaces without smoke development — and is therefore directly approvable without compensating measures like sprinkler systems or extra fire membranes.
How does CemPU meet acoustic requirements for classrooms?
CemPU's standard panel reaches R'w 42–48 dB on shared walls — sufficient for residential separation but not automatically sufficient for classroom walls requiring 50 dB. Two solutions:
1. Reinforced CemPU panel: Tekment produces on order an "acoustic version" with 30% thicker cement boards — reaching R'w 50–52 dB. Used for classroom/classroom walls.
2. Double-skin construction: CemPU + 50 mm acoustic insulation + 12.5 mm gypsum board — reaching R'w 55+ dB. Used for particularly sound-sensitive areas (music rooms, treatment rooms).
Both solutions are tested by 103 ApS with report. We include acoustic evidence in every project package.
How big is the U-value advantage for institutional construction?
BR2006 requires U <0.15 W/m²K on institutional external wall in cold areas. CemPU 336 mm delivers 0.079 W/m²K — almost half as much as the requirement. This means:
1. Over-dimensioning = robustness: If the building in 10–20 years gets changed use or higher user count, it has built-in margin without breaking rules.
2. Lower operating budget: A settlement school of 400 m² with U 0.079 vs. U 0.15 typically saves DKK 60,000–90,000/year in heating — over 30 years it becomes DKK 2–3 million.
3. Better indoor climate: Stable internal surface temperatures reduce condensation risk and improve comfort for pupils and staff during long winter months.
Which settlement institutional projects has Tekment delivered?
Tekment has delivered CemPU for both concrete projects and consultancy assessments of Greenlandic institutions. Typical projects include:
1. Settlement schools (200–500 m²): 1–2 storeys, 4–8 classrooms, teachers' room, specialist rooms, gymnasium. Container delivery with 100–150 m² wall per unit — typically 4–8 containers per school.
2. Daycare centres (150–300 m²): 1 storey, 3–6 group rooms, sleeping room, cloakroom, kitchen. Typically delivered as finished panels installed in 5–7 days.
3. Health centres (300–600 m²): 1–2 storeys with treatment rooms, waiting room, storage. Extra acoustic requirements (privacy) handled with double-skin construction.
All projects are delivered with full BR2006 documentation pack (LCA, fire, acoustics, structural) ready for authority review.
Frequently asked questions
Can CemPU be used for schools and daycare centres in Greenland?
Yes. CemPU's fire class A2-s1,d0 per EN 13501-1 meets the BR2006 requirements directly without compensating measures like sprinkler systems.
How high are BR2006's acoustic requirements?
R'w at least 50 dB between classrooms, 55 dB between classroom and corridor. Standard CemPU reaches 42–48 dB; the acoustic version reaches 50–55 dB.
What is the U-value requirement for institutional construction in Greenland?
BR2006 requires U-value below 0.15 W/m²K on external wall in cold areas. CemPU 336 mm delivers 0.079 — almost half as much.
How long does installation of a settlement school take?
Typically 5–11 days to weathertight shell for a school of 200–500 m² — independent of temperature. This makes the entire building season usable.
What institutions are typical projects?
Settlement schools (200–500 m²), daycare centres (150–300 m²), health centres (300–600 m²) and municipal office buildings. All delivered with full BR2006 documentation.