1. The system must carry the craftsmanship, not the other way around
Danish craftsmen are skilled. Even so, many projects end in drying problems, thermal bridges and mould. That is not their fault — it is a system problem. We still build as if moisture, weather and time were unlimited resources. They are not anymore.
Tekment's choice: let the factory do what the factory is good at — millimetre-precise panels in controlled conditions. And let the craftsman do what the craftsman is good at: install finished panels and complete the details with pride.
2. CO₂ must be a design parameter, not a final report
BR25 sets limits for CO₂e/m²/year. The EU taxonomy is squeezing construction finance. Yet in far too many projects the CO₂ account is only produced at the end — when there is no budget for changes.
Our choice: CO₂ transparency from the first drawing. We deliver an LCA client report (EN 15804+A2) that consultants can use directly in BR18/BR23 calculations. No assumptions. No delay.
3. Time is a climate item
Every week of delay means extra construction loan interest, extra electric heater consumption, extra site cabin hours. Time is not just economics — it is CO₂. A weathertight shell in 5 days instead of 5 weeks saves climate impact in Module A5 that is hard to recover elsewhere.
Our choice: time included in the climate account, not just the budget. When prefab panels reduce build time, we count the A5 saving too. Documented.
4. Documentation is not an attachment
Developers, architects and engineers spend far too much time chasing documentation in arrears: missing fire reports, U-value calculations that don't match the LCA, acoustic reports that don't cover the actual build-up.
Our choice: the documentation pack is the product. DBI fire report (REI 30), 103 ApS acoustic calculation (R_w ≈ 43 dB), Energihuset structural report (18.235), LCA per EN 15804+A2. Everything with a correct reference to the actual panel build-up.
5. We owe the next generation built quality that lasts
A detached house built today must last until 2080. A multi-storey building even longer. Mould in the 2030s will be a catastrophic indoor-climate problem if we don't build moisture-safely now. And thermal bridges that eat 20–30% of the heat will become more expensive every time oil, gas or district heating prices rise.
Our choice: inorganic envelopes without an organic core. Cetris cement particle boards (A2-s1, d0) outside and inside. Closed-cell PU core that does not absorb water. No place where mould can take hold. Built to last.
How you can use the manifesto
If you are an architect, engineer, developer or contractor and recognise yourself in one or more of the points, get in touch. We answer with figures — not sales talk. A 20-minute project review costs nothing and tells you concretely whether CemPU fits your project.